//water// //page 1.88 example 4// clc conc_SH=1/1000//in terms of g/lit// strength_SH=conc_SH*1000//in terms of mgs/lit// volume_SH=50//in terms of ml// volume_H=50//in terms of ml// EDTA_SH=45//volume for Std hardwater(ml)// EDTA_H=25//volume for sample hardwater(ml)// AB_EDTA=15//volume required after boiling(ml)// CaCO3_equivalent_SH=strength_SH*volume_SH//in terms of CaCO3 equivalent// one_ml_EDTA=CaCO3_equivalent_SH/EDTA_SH//in terms of CaCO3 equivalent// To_sample=one_ml_EDTA*EDTA_H/volume_H//total hardness for given volume// To=To_sample*1000//total hardness per litre(ppm)// P_sample=AB_EDTA*one_ml_EDTA/volume_H//permanent hardness for given volume// P=P_sample*1000//permanent hardness per litre(ppm)// T=To-P printf("\nTotal Hardness is %.2f ppm",To); printf("\nPermanent Hardness is %.2f ppm",P); printf("\nTemporary Hardness is %.2f ppm",T);