clc;clear; //Example 14.8 //given values V1=50; T1=14; V2=20; T2=32; RH2=60; //from psychrometric chart h1=39.4; w1=0.010; v1=0.826; h2=79; w2=0.0182; v2=0.889; //calculations ma1=V1/v1; ma2=V2/v2; ma3=ma1+ma2; //from Eq 14-24 w3=(w2*ma2+w1*ma1)/(ma1+ma2); h3=(h2*ma2+h1*ma1)/(ma1+ma2); disp(w3,'the specific humidity in kg of water/kg of dry air'); //from psychrometric chart T3=19; RH3=0.89; v3=0.844; V3=ma3*v3; disp(RH3,'the relative humidity'); disp(T3,'the dry-bulb temperature in C'); disp(V3,'the volume flow rate of the mixture in m^3/min ')