clc //initialisation of variables p=14.2//psia t=140//F r=6//ratio p1=1300//Btu h1=53.3//ft t1=460//F p2=14.0//ft w=0.1715//ft w1=172.0//ft v=2.64//cu ft per lb v1=15.86//cu ft per lb h2=600//ft x1=517500//ft-lb per lb //CALCULATIONS V=1*h1*(t+t1)/(144*p2)//cu ft per lb P=p2*(r)^1.4//psia P1=(t+t1)*r^0.4//R V1=V/r//cu ft per lb Q=p1/w//R T=P1+Q//R P2=w1*(T/P1)//psia T1=T/(r)^0.4//R P3=P2/(r)^1.4//Psia W=1*w*(T1-h2)//Btu per lb Q=p1-W//Btu per lb W1=Q/p1*100//percent E=(1-(1/(r)^0.4))*100//percent M=x1/((v1-v)*144)//psia //RESULTS printf('The mean efficiency pressure=% f psia',M)