// FUNDAMENTALS OF ELECTICAL MACHINES // M.A.SALAM // NAROSA PUBLISHING HOUSE // SECOND EDITION // Chapter 9 : SYNCHRONOUS GENERATOR // Example : 9.2 clc;clear; // clears the console and command history // Given data P = 8 // number of poles m = 3 // number of phase S = 144 // number of slots // caclulations T_p = S/P // pole pitch interms of slots slots_1 = 180/T_p // pole pitch per slots y = 2*slots_1 // short pitch angle in degree k_p = cosd(y/2) // pitch factor // display the result disp("Example 9.2 solution"); printf(" \n Pitch factor is \n k_p = %.2f \n", k_p );