//Ex14_1 Refer fig 14.1(b) and (c) clc n=3 disp("n= "+string(n))// Number of bits L=2^(n) disp("L=2^(n)= "+string(L))// Number of quantization levels VFS=10 disp("VFS= "+string(VFS)+" volts") // Maximum value of analog input voltage Q.E=VFS/L disp("Q.E=VFS/L= "+string(Q.E))// Quantization error disp("Q.E= +0.625,-0.625")// To make Quantization error symmetrical ittaken as (-Q.E/2) negative and positive value(+Q.E/2) Resolution=(100/2^(n))//Formulae disp("Resolution=(100/2^(n))= "+string(Resolution)+" percent")//Resolution disp("Resolution= "+string(+Resolution)+" percent,"+string(-Resolution)+" percent")// Since Resolution is (+)as well as (-)