//Ex13_3 clc VT=26*10^(-3) disp("VT= "+string(VT)+" volts") // Thermal voltage RF=100*10^(3) disp("RF= "+string(RF)+ " ohm") // resistance Iso=50*10^(-9) disp(" Iso = "+string(Iso)+" ampere") // Scale factor (as current)directly proportional to cross-section area of EBJ vs=-0.162 disp("vs= "+string(vs)+" volts") // Input voltage vo=Iso*RF*(exp(-vs/VT)) disp("vo=Iso*RF*(exp(-vs/VT))= "+string(vo)+" volts") // Output voltage of Antilog OP-AMP for input1 i.e vs = -0.162 V