//Variable declaration: h = 48.0 //Convective heat transfer coefficient (Btu/h.ft.°F) A = 2*1.5 //Total heat transfer area (ft^2) Ts = 530.0 //Surface temperature of plate (°F) Tm = 105.0 //Maintained temperature of opposite side of plate (°F) kW = 3.4123*10**3 //Units kW in a Btu/h //Calculation: Q = h*A*(Ts-Tm) //Heat transfer rate in Btu/h (Btu/h) Q1 = Q/kW //Heat transfer rate in kW (kW) //Result: printf("The heat transfer rate in Btu/h is : %f Btu/h.",Q) printf("The heat transfer rate in kW is : %.2f kW.",Q1)