//Variable declaration: qs1 = 5000.0 //Volumetric flow rate of C6H5Cl at standard conditions (scfm) qs2 = 3000.0 //Volumetric flow rate of air at standard conditions (scfm) Ta = 70+460.0 //Actual absolute temperature in Rankine scale (°R) Ts = 60+460.0 //Standard absolute temperature in Rankine scale (°R) V = 387.0 //Volume occupied by one lbmol of any ideal gas (ft^3) M1 = 112.5 //Molecular weight of C6H5Cl (lb/lbmol) M2 = 29.0 //Molecular weight of air (lb/lbmol) T = 60.0 //Absolute temperature (°F) //Calculations: qa1 = qs1*(Ta/Ts) //Volumetric flow rate of C6H5Cl at actual conditions (acfm) qa2 = qs2*(Ta/Ts) //Volumetric flow rate of air at actual conditions (acfm) n1 = qa1/V //Molar flow rate of C6H5Cl (lbmol/min) n2 = qa2/V //Molar flow rate of air (lbmol/min) m1 = n1*M1*T //Mass flow rate of C6H5Cl (lb/h) m2 = n2*M2*T //Mass flow rate of air (lb/h) m_in = m1+m2 //Total mass flow rate of both streams entering the oxidizer (lb/h) m_out = m_in //Total mass flow rate of both streams exit the cooler (lb/h) //Result: printf("The rate of the products exit the cooler is : %.0f lb/h",m_out)