//Variable declaration: //From example 19.5: Q = -4435.2 //Heat rate with insulation (W) R2 = 0.00198 //Convection thermal resistance ( C/W) T3 = 26 //Surrounding air temperature ( C) h = 21 //Convective heat transfer coefficient between the air and the surface (W/m^2.K) k = 0.0433 //Thermal conductivity of cork board insulation (W/m.K) L = 0.00825 //Required insulation thickness (m) //Calculation: T2 = T3+Q*R2 //Interface temperature ( C) (part 1) Bi = h*L/k //Biot number (part 2) //Result: printf("1. The interface temperature is : %.2f C .",T2) printf("2. The Biot number is : %.0f ",Bi) printf("3. Theoretical part.")