clear ; clc; // Example 5.14 printf('Example 5.14\n\n'); printf('Page No. 137\n\n'); // given T1 = 25;// Wet-bulb temperature in degree celcius T2 = 40;//Dry-bulb temperature in degree celcius //By using the humidity chart and steam tables for air-water mixtures at the given temperatures, the all following data can be obtained //(a) humidity w = 0.014;// in kg/kg printf('the required humidity is %.3f kg/kg \n',w) //(b) relative humidity R_H = 30;// in percentage printf('the required relative humidity in percentage is %.0f\n\n',R_H) //(c) the dew point T_w = 20;// in degree celcius printf('the required dew-point temperature is %.0f deg C\n',T_w) //(d) the humid heat Cpa = 1.006*10^3;// Heat Capacity of bone dry air in J/kg-K Cpwv = 1.89*10^3;// Heat Capacity of water vapour in J/kg-K S = Cpa + (w*Cpwv);//in J/kg-K printf('the humid heat is %.0f J/kg-K\n\n',S ) //(e) the humid volume V_G = ((1/29)+(w/18))*22.41*((T2 + 273)/273);//in m^3/kg printf('the humid volume is %.3f m^3/kg \n',V_G) //(f) adiabatic process w_A = 0.020;// in kg/kg printf('the humidity of the mixture if saturated adiabatically is %.3f kg/kg \n\n',w_A) // (h) isothermal process w_i = 0.049;// in kg/kg printf('the humidity of the mixture if saturated isothermally is %.3f kg/kg \n',w_i)