clc clear Ma=18000; //in kg/hr P=12; //in bar x=0.97; //Dryness Fraction CV=27400; //in kJ/kg Mf=2050; //in kg>hr Qs=Mf*CV; printf('Heat Supplied per hour: %3.1f kJ/hr',Qs); printf('\n'); //At 12 bar Hf=798.6; //in kJ/kg Hfg=1986.2; //in kJ/kg H1=Hf+(x*Hfg); //At 105 C Hfw=438.9; //in kJ/kg Eff=(Ma*100*(H1-Hfw))/Qs; printf('Thermal Efficiency: %3.2f Percent',Eff); printf('\n'); Ms=Ma/Mf; printf('Factor of Evaporation: %3.2f ',Ms); printf('\n');