clc clear //Conditions at 8 bar P=8; //Pressure in bar x=0.9; //dryness fraction Hf=721.1; //in kJ/kg Hfg=2048.0; //in kJ/kg Vg=0.240; //in m^3/kg H1=Hf+(x*Hfg); V1=x*Vg; //Enthalpy of superheated steam at 8 bar and 200 Celcius Hg=2769.1; Cps=2.1; Tsup=200+273; //in Celcius Tsat=170.4+273; //in Celcius H2=Hg+(Cps*(Tsup-Tsat)); V2=(Vg*Tsup)/Tsat; H=H2-H1; printf('Heat supplied: %3.1f kJ/kg',H); printf('\n'); W=P*100*(V2-V1); printf('Work Done: %3.3f kJ/kg',W); printf('\n'); //At 8 bar Sf=2.046; //in kJ/kg K Sfg=4.617; //in kJ/kg K Sg=6.663; //in kJ/kg K S1=Sf+(x*Sfg); S2=Sg+(Cps*(log(Tsup/Tsat))); S=S2-S1; printf('The Enthalpy change during process: %3.1f kJ/kg K',S); printf('\n');