//Example 1_25 clc; clear;close; //Given data: T1=120;//degreeC(Junction Temperature) T2=35;//degreeC(Ambient Temperature) P=40;//W theta_dash=0.8;//degree C/W(junction to heat sink) theta=(T1-T2)/P;//degree C/W disp(theta-theta_dash,"Resistance of heat sink in degree C/W");