//Exa 6.34 clc; clear; close; format('v',7); //Given Data : p1=80;//bar Tsup3=350;//degree C pb=712.5/760*1.01325;//bar mdot=2;//Kg/s //mdot=1;//Kg h3=2964;//KJ/Kg(Molliers diagram) h4=2184;//KJ/Kg(Molliers diagram) WT=h3-h4;//KJ/Kg WTdot=mdot*WT;//KW disp(WTdot,"Total turbine work in KW : "); wp=(p1-pb)/10;//KJ/Kg hf1=411.35;//KJ/Kg(from steam table) h1=hf1;//KJ/Kg h2=h1+wp;//KJ/Kg qi=h3-h2;//KJ/Kg EtaR=(WT-wp)/qi*100;//% disp(EtaR,"Rankine efficiency in % : "); //Steam table is used to get some data.