//Example 6.17 clc; clear; close; format('v',5); //Given data : g=9.81;//constant d=1.2;//meter do=50/1000;//meter H=3;//meter Cd=0.6;//Coefficient of discharge ao=%pi/4*do^2;//m^2 A=%pi/4*d^2;//m^2 t=2*A*sqrt(H)/Cd/ao/sqrt(2*g);//sec disp("Time taken for emptying the tank is "+string(floor(t/60))+" minute "+string((t/60-floor(t/60))*60)+" seconds.");