//Example 6.14 clc; clear; close; format('v',6); //Given data : g=9.81;//constant Cd=0.6;//Coefficient of discharge B=1600/1000;//meter D=1250/1000;//meter ao=1.6*1.25;//m^2 H1=2+1.25/2;//meter H2=0.8+1.25/2;//meter H=H1-H2;//meter Q=Cd*ao*sqrt(2*g*H);//m^3/sec or Cumec disp(Q,"Discharge in Cumec : "); //Answer is wrong in the book.