// Exa 6.22 clc; clear; close; // Given data I_DSS= 12;// in mA I_DSS= I_DSS*10^-3;// in A V_P= -4;// in V R_D= 3;// in kΩ R_D= R_D*10^3;// in Ω Rs= 0;// in Ω V_DD= 15;// in V V_GS= -2;// in V I_D= I_DSS*(1-V_GS/V_P)^2;// in A disp(I_D*10^3,"The value of I_D in mA is :") V_DS= -I_D*R_D+V_DD;// in V disp(V_DS,"The value of V_DS in volts is :") if V_DS>V_GS-V_P then disp("The device is operating in the saturation region") end