//example 3.18 //Calculate //consumptive use //consumptive irrigatin requirement //field irrigatio reqiurement clc; //Given eita=0.7; //water application efficiency k=0.75; //crop factor T=[19 16 12.5 13]; //given values of temperature p=[7.19 7.15 7.30 7.03]; //daytime hours of the year RD=1.2; //rainfall in december RJ=0.8; //rainfall in january for i=1:4 f(i)=p(i)*(1.8*T(i)+32)/40; end s=0; for i=1:4 s=s+f(i); end C=k*s; R=RD+RJ; CIR=C-R; FIR=CIR/eita; C=round(10*C)/10; CIR=round(CIR*10)/10; FIR=round(FIR*10)/10; mprintf("Consumptive use=%f cm.",C); mprintf("\nconsumptive irrigatin requirement=%f cm.",CIR); mprintf("\nfield irrigatio reqiurement=%f cm.",FIR);