//Chapter-11 example 55 //============================================================================= clc; clear; //input data Pav = 200;//average power in watts PRF = 1000;//pulse repetitive frequency in Hz PW = 1*10^-6;//pulse width in sec Pmin = 1*10^-12;//minimum receivable power Ac = 10;//area of capture in m^s RCS = 2;//radar cross sectional area in m^2 Vo = 3*10^8;//vel of Em wave in m/s; lamda = 0.1;//wavelength in cms //calculations F = Vo/lamda;//operating frequency in hz Pt = Pav/(PRF*PW); Rmax = ((Pt*Ac*Ac*RCS)/(4*%pi*lamda*lamda*Pmin))^0.25; //output mprintf('Operating frequency is %g Ghz\n Radar peak power is %g KW\n Maximum Radar range of the Radar system is %g Km\n',F/10^9,Pt/1000,Rmax/1000); //==============end of the program=============================================