// Chapter6 // Page.No-220, Figure.No-6.17 // Example_6_10 // Range of input voltage // Given clear;clc; R1min=1*10^3;R1max=6.8*10^3; io=1*10^-3; // Meter current for full-wave rectification vin_min=1.1*R1min*io; // Minimum input voltage printf("\n Minimum input voltage is = %.1f V \n",vin_min) vin_max=1.1*R1max*io; // Maximum input voltage printf("\n Maximum input voltage is = %.2f V \n",vin_max)