//example 12.5 //page 457 clc; funcprot(0); //initialisation of variable H=60; sigma_critical=0.08; Pa=98000;//pressure Pv=1707;//pressure of vapour Gamma=9810; HL=1; NPSH_min=H*sigma_critical; Hs_max=Pa/Gamma-Pv/Gamma-NPSH_min-HL; disp(Hs_max,"maximum value of suction lift (m)"); clear