clc clear //input data Hi=0.25//Vaccum gauge reading in m of Hg vaccum P0=1.5//Pressure gauge reading in bar Z01=0.5//Effective height between gauges in m P=22//Power of electric motor in kW Di=0.15//Inlet diameter in m Do=0.15//Outlet diameter in m Q=0.1//Discharge of pump in m^3/s dHg=13600//Density of mercury in kg/m^3 dw=1000//Density of water in kg/m^3 g=9.81//Acceleration due to gravity in m/s^2 //calculations Pi=dHg*g*Hi//Inlet pressure in N/m^2 vaccum Po=P0*10^5//Outlet pressure in N/m^2 V0=Q/((3.1415*Do^2)/4)//Velocity of water in delivery pipe in m/s Vi=V0//vleocity of water in suction pipe in m/s Hm=((Po+Pi)/(dw*g))+((V0^2-Vi^2)/(2*g))+(Z01)//Manometric head in m n0=(dw*g*Q*Hm)/(P*10^3)//Overall efficiency //output printf('(a)Manometric head is %3.2f m\n(b)Overall efficiency is %3.3f',Hm,n0)