//Chapter-6,Example 6_8,Page 6-29 clc() //Given Values: u0=4*%pi*10^-7 //Permeability in vacuum A=0.2*10^-4 //Crosss sectional area of iron bar in m^2 H=1600 //magnetising field in A/m phi=2.4*10^-5 //Magnetic flux in weber //Calculations: //We know, phi=B*A B=phi/A //Flux density u=B/H //magnetic permeability ur=u/u0 //relative permeability xm=ur-1 //susceptibility of the iron bar printf('magnetic permeability of iron bar is =%.6f N/(A^2) \n \n',u) printf(' susceptibility of the iron bar is =%.2f \n',xm)