// Example 1.72 clc;clear;close; // Given data format('v',6); V=500;//in Volt f1=50;//in Hz phase=3;//no. of phase P=6;//no. of poles Nr=995;//in rpm Pm=20;//mech power in KW StatorLoss=1500;//in watts pf=0.87;//power facator //calculations Ns=f1*120/P;//in rpm S=(Ns-Nr)/Ns;//slip disp(S,"(a) Slip is : "); Prc=S/(1-S)*Pm*1000;//in watts disp(Prc,"(b) Rotor I^2*R Loss in watts : "); RotorInput=Prc/S;//in watts TotalInput=RotorInput+StatorLoss;//in watts disp(TotalInput/1000,"(c) Total input in KW : "); LineCurrent=TotalInput/sqrt(3)/V/pf;//in Ampere disp(LineCurrent,"(d) Line current in Ampere : ") fr=S*f1;//in Hz disp(fr,"Rotor frequency in HZ : ");