// Example 1.55 clear; clc; close; format('v',7); // Given data TmByTfl=2.2;//ratio R2=0.5;//in ohm per phase X2=5;//in ohm per phase K=70;//tapping in % //Calculations //Formula :Tst proportional to E2^2*R2/(R2^2+X2^2) //Formula :Tm proportional to E2^2/(2*X2) //Formula :Tfl proportional to 1/4.4*E2^2/X2 TstByTfl=R2/(R2^2+X2^2)*TmByTfl*2*X2;//ratio for direct on line disp(TstByTfl,"Ratio of starting torque to full load torque for direct on line starter : "); TstByTfl=(1/sqrt(3))^2*R2/(R2^2+X2^2)*TmByTfl*2*X2;//ratio for star delta starting disp(TstByTfl,"Ratio of starting torque to full load torque for star delta starter : "); TstByTfl=(K/100)^2*R2/(R2^2+X2^2)*TmByTfl*2*X2;//ratio for auto transformer starting disp(TstByTfl,"Ratio of starting torque to full load torque for auto transformer starter : ");