clc clear //INPUT DATA t21=335.19;//temperature in K t3=343.19;//temperature in K cp=0.64;//Specific pressure m=0.008;//mass flow rate in kg/s p1=4.4962;//pressure in MPa p2=1.6;//pressure in MPa hf1=47.26;//enthalpy in kJ/kg hfg1=145.30;//enthalpy in kJ/kg hg1=192.56;//enthalpy in kJ/kg hf2=98.19;//enthalpy in kJ/kg hfg2=111.62;//enthalpy in kJ/kg hg2=209.81;//enthalpy in kJ/kg sf1=0.1817;//entropy in kJ/kgK sf2=0.6913;//entropy in kJ/kgK sg1=0.3329;//entropy in kJ/kgK sg2=0.6758;//entropy in kJ/kgK t2=343;//from t-s diagram temperature in K //CALCULATIONS h2=hg2+cp*(t2-t3);//enthalpy in kJ/kg wc=m*(h2-hg1);//compressor work in kJ/s Rc=m*(hg1-hf2);//Refrigiration capacity in kW Rc1=Rc*60/210;//Refrigiration capacity in TR copv=Rc/wc;//COP of VCR system //OUTPUT printf('(a)The compressive work input is %3.2f kJ/s \n (b)Refrigiration capacity is %3.4f TR \n (c)COPvcr is %3.3f \n',wc,Rc1,copv)