//Exa 3.14 clc; clear; close; //Given data : //Part (i) : without heat sink ThetaMax=90;//in degree C Theta_o=30;//in degree C R=300;//in degree C/W Pr=(ThetaMax-Theta_o)/R;//in watt disp(Pr,"Without heat sink, Maximum permissible power dissipatio in watt :"); //Part (ii) : with heat sink ThetaMax=90;//in degree C Theta_o=30;//in degree C R=60;//in degree C/W Pr=(ThetaMax-Theta_o)/R;//in watt disp(Pr,"With heat sink, Maximum permissible power dissipatio in watt :");