//Exa 10.6 clc; clear; close; //given data format('v',15); R=4160;// in J/kg-K M=2; D_AB=1.944*10^-8;// in m^2/s R_H2=R/M; S=2*0.0532; // Solubility of hydrogen at a pressure of 2 atm in cm^3/cm^3 of pipe P=2;// in atm P=P*1.03*10^5;// N/m^2 T=25;// in degree C T=T+273;// in K r1=2.5;// in mm r1=r1*10^-3;// in m r2=5;// in mm r2=r2*10^-3;// in m del_x=r2-r1;// in m L=1;// in m //Formula P*V= m*R*T V=S; m=P*V/(R*T);// in kg/m^3 of pipe // So, Concentration of H2 at inner surface of the pipe C_A1=0.0176;// in kg/m^3 // The resistance of diffusion of H2 away from the outer surface is negligible i.e. C_A2=0; Am=2*%pi*L*del_x/log(r2/r1); // Loss of H2 by diffusion M_A= D_AB*(C_A1-C_A2)*Am/del_x; disp(M_A,"Loss of H2 by diffusion in kg/s"); //Note: In the book , they put wrong value of C_A1 to calculate M_A, so the answer in the book is wrong