clc //Initialization of variables x=0.8 //calculations disp("From molier diagram,") h1=1357 //500 psia 700F h2=1194 //P2=100 psia h3=1379 //100 psia, 700 F h4=1047 //p4=2 psia h5=93.99 //sat liq at 2 psia h6=95.02 //example 12.1 h2d=h1- x*(h1-h2) h4d=h3- x*(h3-h4) W=(h1-h2d) +(h3-h4d) - (h6-h5) Q=(h1-h6) + (h3-h2d) eta=W/Q //results printf("Thermal efficiency = %d percent",eta*100+1)