clc;funcprot(0);//EXAMPLE 8.6 // Initialisation of Variables t0=5;.......//Assming we are able to purchase only 5-cm thick stock t02=1;......//Thickness of strip in cm tf=0.182;......//Final thickness of strip in cm %CW2=80;.......//cold work of a strip in percent M=1085;.......// The melting point of copper in degree celsius //CALCULATIONS %CW=((t0-tf)/t0)*100;.......//Cold work between from 5 to 0.182 cm in percent tf2=(1-(%CW2/100))*t0;.....// Final Thickness of strip in cm Tr=0.4*(M+273);...// Recrystallization temperature By using 0.4Tm relationship in degree celsius %CW3=((t02-tf)/t02)*100;.....//Cold work of the strip of 1 cm thickness disp(%CW,"Cold work between from 5 to 0.182 cm in percent:") disp(tf2,"1. Final Thickness of strip in cm") disp(Tr-273,"2. Recrystallization temperature By using 0.4Tm relationship in degree celsius:") disp(%CW3,"3. Cold work of the strip of 1 cm thickness :")