close(); clear; clc; //initial temperature 'T1', final temperature 'T2', leakage current doubles for 't' increase in temperature T1 = 25; //degree C T2 = 90; //degree C t = 6; //degree C Icbo1 = 500*10^(-9); //A Icbo2 = Icbo1*2^((T2-T1)/t); //A mprintf("Leakage current at %d degree C, Icbo2 = %0.2f uA",T2,Icbo2*10^6)