//Speed n, Flux per pole phi, Total number of conductors z //Maximum line current Ia close(); clear; clc; p = 4; n = 1800;//rpm z = 728; Ia = 100;//A phi = 30*10^(-3);//Wb //Since armature is lap wound p=a a = p; E = phi*n*z/60*p/a; P = E*Ia; mprintf('Maximum Power developed by the armature P = %0.1f kW',P/1000);