//Speed n, Flux per pole phi, Total number of conductors z close(); clear; clc; p = 4; n = 1800;//rpm z = 728; phi = 30*10^(-3);//Wb //Since armature is lap wound p=a a = p; E = phi*n*z/60*p/a; mprintf('Voltage induced in armature winding, E = %0.1f V',E);