//CHAPTER 8- DIRECT CURRENT MACHINES //Example 21 disp("CHAPTER 8"); disp("EXAMPLE 21"); //10kW 6 pole DC generator //VARIABLE INITIALIZATION p_o=10*1000; //in Watts P=6; //number of poles E_g=200; //in Volts N=1500; //in rpm A=P; //since the armature is lap connected B=0.9; //flux density in Tesla l=0.25; //length of armature in m dia=0.2; //diameter of armature in m //SOLUTION //solution (a) //pole pitch is defined as the periphery of armature divided by the number of poles or the area of armature between two adjacent poles //area of armature = 2.pi. dia of armature. length of armature area=2*%pi*(dia/2)*l; //area of armature phi=B*area; //flux density over one pitch pole= flux per pole/area of armature between poles disp(sprintf("(a) The flux per pole is %.4f Wb",phi)); //solution (b) Z=(60*E_g)/(phi*N); // no of conductors in the armature //induced emf = phi.Z.N.P/60.A // = phi.Z.N/60 ( as A=P) disp(sprintf("(b) The total number of active conductors is %d",Z)); //solution (c) I_a=50; // armature current p=E_g*I_a; //power developed w=(2*%pi*N)/60; //speed in RPS T=p/w; //Torque disp(sprintf("(c) The torque developed when armature current is 50 A is %.2f N-m",T)); //END