// Example 7.10 // Calculation of Wattmeter Readings // Assuming phase_a= 0; V_ab_m= 780; // Line voltage phase_ab= 30; // in degree I_a_m=30; // in Amphere phase_a=-36.9;//in degree V_cb_m= 780; phase_cb=90; I_c_m=30; phase_c=83.1; x_ab=V_ab_m*cos(phase_ab*(%pi/180)) y_ab=V_ab_m*sin(phase_ab*(%pi/180)) V_ab=complex(x_ab,y_ab); // Line voltage a-b in rectangular form x_a=I_a_m*cos(phase_a*(%pi/180)) y_a=I_a_m*sin(phase_a*(%pi/180)) I_a=complex(x_a,y_a); // Line current in rectangular form x_cb=V_cb_m*cos(phase_cb*(%pi/180)) y_cb=V_cb_m*sin(phase_cb*(%pi/180)) V_cb=complex(x_cb,y_cb); x_c=I_c_m*cos(phase_c*(%pi/180)) y_c=I_c_m*sin(phase_c*(%pi/180)) I_c=complex(x_c,y_c); P_1=real(V_ab*I_a'); P_2=real(V_cb*I_c'); // So P=P_1+P_2; Q=sqrt(3)*abs(P_2-P_1); disp(P,"Total Average power supplied by generator(in Watts)=") disp(Q,"Reactive power supplied by the generator(in VAr)=")