//ques-1.17 //Calculating Hardness of solution clc m=0.5//mass of CaCO3 eq (in g) v1=48;//volume of EDTA used for titration (in mL) v2=15;//volume of EDTA used before boiling (in mL) v3=10;//volume of EDTA used after boiling (in mL) V=50;//volume of hard water used (in mL) //500mL SHW = 500mg of CaCO3 eq //48mL EDTA = 50mg CaCO3 eq c=50/48;//CaCO3 eq for 1mL EDTA solution (in mg) total=v2*c*(1000/V);//total hardness (in ppm) nc=v3*c*(1000/V);//non-carbonate hardness (in ppm) c=total-nc;//carbonate hardness (in ppm) printf("Non-carbonate hardness in given water sample is %.1f ppm and Carbonate hardness is %.1f ppm.",nc,c);