//EXAMPLE 27.3(a) //4-POLE MOTOR clc; funcprot(0); //Variable Initialisation P=4;...........//Total number of poles Z=880;.........//Total number of conductors Ia=120;.......//Armature current in Amperes b=3;..........//Brush lead in degrees Aw=2;.......//Number of parallel paths for a wave wound generator fdw=1100;......//Demagnetizing the field winding has 1100 turns per pole I=Ia/Aw;......//Current per path in Amperes ATd=Z*I*b/360;.......//Demagnetizing ampere-turns per pole ATe=Z*I*((1/(2*P))-(b/360));.....//Cross-magnetizinfampere-turns per pole disp(ATd,"(a).Demagnetizing ampere-turns per pole:"); disp(ATe,"(b).Cross-magnetizinfampere-turns per pole:"); Afc=ATd/fdw;........//Additional field current in Amperes disp(Afc,"(c).Additional field current in Amperes:");