//Chapter-12, Example 12.7, Page 516 //============================================================================= clc clear //INPUT DATA T=100;//Temperature of saturated steam in degree C t1=30;//Inlet temperature of water in degree C t2=70;//Exit temperature of water in degree C //CALCULATIONS //COUNTER FLOW Tc=(T-t2);//Temperature difference between saturated steam and exit water temperature in degree C tc=(T-t1);//Temperature difference between saturated steam and inlet water temperature in degree C Tlmc=((Tc-tc)/log(Tc/tc));//LMTD for counter flow in degree C //PARALLEL FLOW Tp=(T-t1);//Temperature difference between saturated steam and inlet water temperature in degree C tp=(T-t2);//Temperature difference between saturated steam and exit water temperature in degree C Tlmp=((Tp-tp)/log(Tp/tp));//LMTD for counter flow in degree C //CROSS FLOW R=((T-T)/(t2-t1));//R value for Correction factor F P=((t2-t1)/(T-t1));//P value for Correction Factor F F=1;//Referring to Fig.12.12 in page no 515 Tlmx=(F*Tlmc);//LMTD for cross flow in degree C //OUTPUT mprintf('The effective log mean temperature difference for: \n i)COUNTER FLOW is %3.1f degree C \n ii)PARALLEL FLOW is %3.1f degree C \n iii)CROSS FLOW is %3.1f degree C',Tlmc,Tlmp,Tlmx) //=================================END OF PROGRAM==============================