//Chapter-12, Example 12.17, Page 533 //============================================================================= clc clear //INPUT DATA Tci=20;//Inlet temperature of water in degree C Tco=50;//Outlet temperature of water in degree C Th=120;//Temperature at which steam condenses in degree C newTci=15;//New Inlet temperature of water in degree C //CALCULATIONS newTco=(((Tco-Tci)*(Th-newTci))/(Th-Tci))+newTci;//New outlet temperature of water in degree C //OUTPUT mprintf('New outlet temperature of water is %3.1f degree C',newTco) //=================================END OF PROGRAM==============================