//example2.16 clc disp("No load current I=2.5 A,") n=440*2.5 disp(n,"No load input(in W)= (V*I)=") s=440/550 disp(s,"I_sh(in A)=V/R_sh=") disp("In dc shunt motor, I=(I_sh)+(I_a)") a=2.5-0.8 disp(a,"I_a(in A)=I-(I_sh)=") p=1.2*(1.7)^2 format(6) disp(p,"No load armature copper loss(in watts)= (R_a)*(I_a)^2=") disp("Constant losses= No load input- No lpad armature Cu losses") c=1100-3.468 format(9) disp(c,"Therefore, Constant losses(in Z)=") disp("Now, full load line current i.e I=32 A") disp("I=(I_sh)+(I_a)") a=32-0.8 disp(a,"I_a(in A)=I-(I_sh)=") p=1.2*(31.2)^2 disp(p,"Full load armature copper loss=(R_a)*(I_a)^2=") disp("Total losses= Full load armature Cu loss + Constant losses") l=1168.128+1096.532 disp(l,"Therefore, Total losses(in W)=") v=440*32 disp(v,"Full load motor input(in W)= V*I =") v=14080-2264.66 disp(v,"Full load motor output(in W)= Input-Losses=") d=(1181534)/14080 format(6) disp(d,"% efficiency at full load= [(Full load Output)/(full load input)]*100=") disp("Therefore, Efficiency of motor at full load = 83.91%")