// Display mode mode(0); // Display warning for floating point exception ieee(1); clear; clc; disp("Turbomachinery Design and Theory,Rama S. R. Gorla and Aijaz A. Khan, Chapter 2, Example 12") disp("Exit blade angle beta2 =20 degres") beta2 = 20; U2 = 56; //U2 in m/s Cr2 = 7.5; //in m/s CW2 = U2 - Cr2/tan(20*%pi/180) disp("Using slip factor :") sigma = 0.88 disp("The velocity whirl at exit is :") Cw2 = sigma*CW2 disp("Work input per kg of water flow in KJ/kg") W = Cw2*U2/1000 disp("Absolute velocity at impeller tip C2 in m/s is :") C2 = (Cr2^2 + Cw2^2)^(1/2)