clc //initialisation of variables Tw= 200 //F Ta= 600 //F V= 100 //fps Di= 0.902 //in d= 0.0375 //lb/cu ft u= 0.000020 //lbm/sec cp= 0.25 //Btu/lb F k= 0.027 //Btu/sq ft hr //CALCULATIONS NRe= (Di*V*d)/(u*12) Npr= 0.66 h= k*0.023*NRe^0.8*Npr^0.4*12/Di //RESULTS printf ('Film coefficient = %.1f Btu/sq ft hr F',h)