clc //initialisation of variables R= 53.31 T= 80 //F P2= 90//psia P1= 15 //psia n= 1.4 n1= 1.3 cv= 0.171 //CALCULATIONS Wk= (n/(n-1))*R*(T+460)*((P2/P1)^((n-1)/n)-1) Wn= (n1/(n1-1))*R*(T+460)*((P2/P1)^((n1-1)/n1)-1) Wt= R*(T+460)*log(P2/P1) nc= Wt/Wn nc1=Wk/Wn ////RESULTS printf ('Thermal effeciency= %.2f ',nc) printf (' \n Isothermal effeciency= %.2f ',nc1)