//Exa:2.3.3 clc; clear; close; P=10000;//in watts I=60;//in amperes V=400;//in volts //When the coil is connected between phase A and Neutral; theta=acosd(P/(V*I/sqrt(3)));//in degrees alpha=90-theta;//in degrees W=V*I*cosd(alpha)/1000; disp(W,'Wattmeter Reading (in watts)=')