// Electric Machinery and Transformers // Irving L kosow // Prentice Hall of India // 2nd editiom // Chapter 7: PARALLEL OPERATION // Example 7-4 clear; clc; close; // Clear the work space and console. // Given data P1 = 300 ; // Power rating of generator 1 in kW P2 = 600 ; // Power rating of generator 2 in kW V = 220 ; // Voltage rating of generator 1 and 2 in volt V_o = 250 ; // No-load voltage applied to both the generators in volt // Assume linear characteristics V_1 = 230 ; // Terminal voltage in volt (case a) V_2 = 240 ; // Terminal voltage in volt (case b) // Calculations // case a kW1_a = (V_o - V_1)/(V_o - V) * P1 ; // kW carried by generator 1 kW2_a = (V_o - V_1)/(V_o - V) * P2 ; // kW carried by generator 2 // case b kW1_b = (V_o - V_2)/(V_o - V) * P1 ; // kW carried by generator 1 kW2_b = (V_o - V_2)/(V_o - V) * P2 ; // kW carried by generator 2 // case c frac_a = (V_o - V_1)/(V_o - V); // Fraction of rated kW carried by each generator frac_b = (V_o - V_2)/(V_o - V); // Fraction of rated kW carried by each generator // Display the results disp("Example 7-4 Solution : "); printf(" \n a: At 230 V, using Eq.(7-3) below : "); printf(" \n Generator 1 carries = %d kW ", kW1_a ); printf(" \n Generator 2 carries = %d kW \n", kW2_a ); printf(" \n b: At 240 V, using Eq.(7-3) below : "); printf(" \n Generator 1 carries = %d kW ", kW1_b ); printf(" \n Generator 2 carries = %d kW \n", kW2_b ); printf(" \n c: Both generators carry no-load at 250 V; "); printf(" \n %f rated load at %d V; ", frac_b , V_2 ); printf(" \n %f rated load at %d V; ", frac_a , V_1 ); printf(" \n and rated load at %d V. ", V );