clc; clear; //Example3.2 //Given mu=15*10^-6 //sq m /s v=2 //m/s L=2 //[m] length of plate Nre_x=3*10^5 xc=Nre_x*mu/v //critical length at whihc the transition takes place //Since xc is less than 2 m.Therefore the flow is laminar //at any distance x,.it is calculated from //del/x=4.64/(sqrt(NRe,x)) //At x=L=2 m Nre_l=v*L/mu del_l=4.64*L/sqrt(Nre_l) del_l=del_l*1000 //[mm] printf("Boundary layerthickness at the trailing edge is %f mm",del_l);