From b1f5c3f8d6671b4331cef1dcebdf63b7a43a3a2b Mon Sep 17 00:00:00 2001 From: priyanka Date: Wed, 24 Jun 2015 15:03:17 +0530 Subject: initial commit / add all books --- 608/CH40/EX40.21/40_21.sce | 14 ++++++++++++++ 1 file changed, 14 insertions(+) create mode 100755 608/CH40/EX40.21/40_21.sce (limited to '608/CH40/EX40.21') diff --git a/608/CH40/EX40.21/40_21.sce b/608/CH40/EX40.21/40_21.sce new file mode 100755 index 000000000..e7769698f --- /dev/null +++ b/608/CH40/EX40.21/40_21.sce @@ -0,0 +1,14 @@ +//Problem 40.21: The total loop inductance of an isolated twin power line is 2.185 μH/m. The diameter of each conductor is 12 mm. Determine the distance between their centres. + +//initializing the variables: +L = 2.185E-6; // in H/m +u0 = 4*%pi*1E-7; +ur = 1; +a = 0.012/2; // in m + +//calculation: +//distance D +D = a*%e^((L*%pi)/(u0*ur) - 0.25) + +printf("\n\n Result \n\n") +printf("\ndistance D is %.2f m",D) \ No newline at end of file -- cgit