From 7f60ea012dd2524dae921a2a35adbf7ef21f2bb6 Mon Sep 17 00:00:00 2001 From: prashantsinalkar Date: Tue, 10 Oct 2017 12:27:19 +0530 Subject: initial commit / add all books --- 3760/CH6/EX6.55/Ex6_55.sce | 20 ++++++++++++++++++++ 1 file changed, 20 insertions(+) create mode 100644 3760/CH6/EX6.55/Ex6_55.sce (limited to '3760/CH6/EX6.55/Ex6_55.sce') diff --git a/3760/CH6/EX6.55/Ex6_55.sce b/3760/CH6/EX6.55/Ex6_55.sce new file mode 100644 index 000000000..07e3fee52 --- /dev/null +++ b/3760/CH6/EX6.55/Ex6_55.sce @@ -0,0 +1,20 @@ +clc; +v=440; // rated voltage of distribution circuit +im=1200; // maximum current that can be supplied +n=0.85; // efficiency of induction motor +pf=0.8; // power factor of motor +ir=5; // ratio of starting current to full load current +disp('case a'); +il=im/ir; //rated line current +p=sqrt(3)*v*il*n*pf; +printf('Maximum KW rating is %f KW\n',p/1000); +disp('case b'); +x=0.8; // rated of applied voltage and stepped down voltage +il=im/(x^2*ir); //rated line current +p=sqrt(3)*v*il*n*pf; +printf('Maximum KW rating is %f KW\n',p/1000); +disp('case c'); +// star-delta converter is same as autotransformer starter with 57.8 % tapping therefore +il=im/(0.578^2*ir); //rated line current +p=sqrt(3)*v*il*n*pf; +printf('Maximum KW rating is %f KW\n',p/1000); -- cgit