From 7f60ea012dd2524dae921a2a35adbf7ef21f2bb6 Mon Sep 17 00:00:00 2001 From: prashantsinalkar Date: Tue, 10 Oct 2017 12:27:19 +0530 Subject: initial commit / add all books --- 3733/CH17/EX17.3/Ex17_3.sce | 30 ++++++++++++++++++++++++++++++ 1 file changed, 30 insertions(+) create mode 100644 3733/CH17/EX17.3/Ex17_3.sce (limited to '3733/CH17/EX17.3') diff --git a/3733/CH17/EX17.3/Ex17_3.sce b/3733/CH17/EX17.3/Ex17_3.sce new file mode 100644 index 000000000..630f14d39 --- /dev/null +++ b/3733/CH17/EX17.3/Ex17_3.sce @@ -0,0 +1,30 @@ +// Example 17_3 +clc;funcprot(0); +//Given data +P=3000;// kW +P_1=10;// bar +T_1=250;// °C +P_c=65;// cm of Hg +P_b=75.2;// cm of Hg +gradT=15;// °C +T_c=35;// The temperature of the condensate in °C +C_pw=4.2;// kJ/kg.°C + +//Calculation +//(a) +p_t=(P_b-P_c)*0.1359;// bar +p_s=p_t;// bar (as p_a=0) +// From h-s chart +x=0.846;// Dryness fraction from h-s chart +h_1=2984;// kJ/kg +h_2=2234;// kJ/kg +h_f2=147;//kJ/kg +gradh=(h_1-h_2);// kJ/kg +m_s=P/gradh;// kg/sec +m_s=m_s*3600;// kg/hr +SSC=m_s/P;// Specific steam consumption in kg/kW-hr +//(b) +n_th=(gradh/(h_1-h_f2))*100;// Thermal efficiency in % +//(c) +m_w=(m_s*(h_2-h_f2))/(gradT*C_pw*1000);//Cooling water supplied in tons/hr. +printf('\n(a)Specific steam consumption=%0.1f kg/kW-hr \n(b)Thermal efficiency of the plant=%0.1f percentage \n(c)Cooling water supplied=%0.0f tons/hr',SSC,n_th,m_w); -- cgit