From 7f60ea012dd2524dae921a2a35adbf7ef21f2bb6 Mon Sep 17 00:00:00 2001 From: prashantsinalkar Date: Tue, 10 Oct 2017 12:27:19 +0530 Subject: initial commit / add all books --- 3681/CH3/EX3.4/Ex3_4.sce | 28 ++++++++++++++++++++++++++++ 1 file changed, 28 insertions(+) create mode 100644 3681/CH3/EX3.4/Ex3_4.sce (limited to '3681/CH3/EX3.4/Ex3_4.sce') diff --git a/3681/CH3/EX3.4/Ex3_4.sce b/3681/CH3/EX3.4/Ex3_4.sce new file mode 100644 index 000000000..999571179 --- /dev/null +++ b/3681/CH3/EX3.4/Ex3_4.sce @@ -0,0 +1,28 @@ +// Estimating the average flux density in the air gap +clc; +disp('Example 3.4, Page No. = 3.14') +// Given Data +MVA = 172;// MVA rating +P = 20;// Number of pole +D = 6.5;// Diameter in meter +L = 1.72;// Core length in meter +ys = 64;//Slot Pitch in mm +Ws = 22;// Stator slot (open) width in mm +lg = 30;// Length of air gap in mm +nd = 41;// Number of ventilating ducts +Wd = 6;// Width of each ventilating Duct in mm +mmf = 27000// Total mmf per pole in A +Kf = 0.7;// Field form factor +// Estimation of effective air gap area per pole +y=Ws/(2*lg);//Ratio for slots +Kcs= (2/%pi)*(atan(y)-log10(sqrt(1+y^2))/y);//Carter's co-efficient for slots +Kgs=ys/(ys-(Kcs*Ws));//Gap contraction for slots +y=Wd/(2*lg);//Ratio for ducts +Kcd= (2/%pi)*(atan(y)-log10(sqrt(1+y^2))/y);//Carter's co-efficient for slots +Kgd=L*10^(3)/(L*10^(3)-(Kcd*nd*Wd));//Gap contraction for ducts +Kg=Kgs*Kgd;//Total gap expansion factor +ATg = 0.87*mmf;// The required for the air gap is 87% of the total mmf per pole in A +Bg = ATg/(800000*Kg*lg*10^(-3));// Maximum flux density in air gap in Wb per meter square +Bav= Kf*Bg;// Average flux density in air gap in Wb per meter square +disp(Bav,'Average flux density in air gap (Wb per meter square)='); +//in book answer is .615 Wb per meter square. The provided in the textbook is wrong -- cgit